W E Anderson Flotect V8 Vane Operated flow switch

Dwyer W E Anderson Flotect V8 series vane operated flow switch

V8 Flotect® Flow Switch Protects Equipment: Operation is simple and dependable.

V8 Flotect® Flow Switch Protects Equipment: Operation is simple and dependable. In most applications, the switch is normally off while there is sufficient flow of liquid or air. When flow stops, the vane spring moves the vane, actuating a single pole double throw switch rated 5A @ 120/250 VAC to start or stop motor, pump, engine, etc. Operate a damper or valve; shut down a burner or actuate an alarm or signal, protecting unattended equipment from damage or loss of production. The V8 Flotect® Flow Switch has a leak proof body and vane constructed of tough durable polyphenylene sulfide which has excellent chemical resistance. The full size trimmable vane is provided with molded-in graduations allowing for installation in a 1 inch through 6 inch pipe. Operating pressures are up to 150 psig (10 bar) and temperatures to 212°F (100°C). The V8 flow switch can be used in various chemical processes, industrial systems and similar applications where process conditions are compatible with polyphenylene sulfide, ceramic 8 and 316SS. The V8 Flotect® flow switch is UL recognized as an industrial motor controller per UL standard 508, suitable for mounting in a protected environment.

Service: Compatible gases or liquids.
Wetted Materials: Vane and Body: Polyphenylene Sulfide (PPS); Pin and Spring: 316 SS on Inconel; Magnet: Ceramic 8.
Temperature Limit: 212°F (100°C).
Pressure Limit: 150 psig (10 bar).
Enclosure Rating: General purpose; WP and WP2 options are weatherproof.
Switch Type: SPDT snap switch; MV option: SPDT gold contact snap switch.
Electrical Rating: 5A @ 125/250 VAC, 5A resistive, 3A inductive @ 30 VDC. MV option: 1A @ 125VAC, 1A resistive, 0.5A inductive @ 30 VDC.
Electrical Connections: 18 AWG 18" (460 mm) long.
Conduit Connection: 1/2" male NPT, 1/2" female NPT on WP and WP2.
Process Connection: 1" male NPT.
Mounting Orientation: Actuation/deactuation flow rates are based on horizontal pipe run and are nominal values. Unit cannot be used with vertical down flow.
Set Point Adjustment: Vane is trimmable.
Weight: 4.5 oz (0.13 kg).
Agency Approvals: CE, UL 508 for US and Canada.